SURTRON 400 HP
Shipped From Abroad
SURTRON 400 HP can be used to simultaneously perform monopolar and bipolar surgery in application fields that require high precision and reliability.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
DOUBLE ACTIVITY ‘OPERATION
• Two output channels for monopolar cutting
• Two independent settings and output channels for monopolar coagulation are more frequent
CONTROLLED CUTTING PROCEDURES
• cutting currents for eschar-free incision
• Cutting current with selectable coagulating property for bleeding-controlled dissection
• Low capacitive coupling by current endoscopic procedures, Slow BLEND
DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * and two operators
• SPRAY COAG is achievable with a handpiece or pedal
WIDE BIPOLAR FEATURES
• Bipolar cutting with bleeding control
• Cutting current Slow BLEND
• Start and stop automatically activate separately
TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability of contact impedance between the patient’s body and the neutral plate is constantly verified by the electronic control Skin Plate Electronic Control called SPEC
• Continuous monitoring of leakage current
• Change in automatically compensated mains voltage before starting the RF power output
CUSTOM PROCEDURES
• Independent choice of coagulation currents and power levels of each of the two operators
• Ten configurable personal procedures and immediately recallable
CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• outputs for connections driven by argon plasma units and smoke aspirator
AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP
• Automatic diagnostic control of the actual complete electronic drive functionality and accessories, connected and coded report of found failures
* Coag SPEEDY is also called Fulgurate or Forced
** Coag DEEP is also called Pin Point, Desicate, or Soft
Technical Data
- Max output power monopolar pure CUT
400 W – 300 Ω - Max output power monopolar cut-coag CUT80%
300 W – 300 Ω - Max output power monopolar cut-coag CUT60%
250 W – 300 Ω - Max output power monopolar cut-coag CUT40%
200 W – 300 Ω - Max output power monopolar cut ENHANCED
250 W – 500 Ω - Max output power monopolar cut-coag BLEND
250 W – 300 Ω - Max output power monopolar coag SPEEDY
120 W – 500 Ω - Max output power monopolar coag DEEP
120 W – 200 Ω - Max output power monopolar coag SPRAY
100 W – 2000 Ω - Max output power monopolar coag SPRAY ARGON
100 W – 2000 Ω - Max output power of bipolar CUT
120 W – 50 Ω - Max output power bipolar cut-coag CUT80%
120 W – 50 Ω - Max output power bipolar cut-coag CUT60%
120 W – 50 Ω - Max output power bipolar cut-coag CUT40%
100 W – 50 Ω - Max output power bipolar cut-coag BLEND
120 W – 150 Ω - Max output power bipolar coag COAG
120 W – 50 Ω - Vessel sealing
200 W – 50 Ω - Working frequency Monopolar / Bipolar
425 kHz / 525 kHz - Patient circuit
F - Selectable input voltage
115 – 230 Vac - Mains frequency
50 – 60 Hz - Electrical input power
1000 VA - Size WxHxD
470x150x400 mm - Weight
17,5 Kgs
CONTROLS
- Patient/Plate circuit monitoring
- Output power monitoring
- Self-check control
- H.F. Leakage currents control
- Compensation for mains fluctuation
SAFETY
- EN60601-1
- EN60601-1-2
- EN60601-2-2
- Level of protection provided by housing: IP21