Highlight

  • New Arrivals
  • Sale
  • Hot items

SURTRON 300 HP

Shipped From Abroad

The SURTRON 300 HP is a high-frequency electrosurgical unit designed for precision monopolar and bipolar procedures. It offers programmable RF power emissions, enabling operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Description

SURTRON 300 HP can be used to simultaneously perform monopolar and bipolar surgery in application fields that require high precision and reliability.

Key Features
  • Surgical ModesSupports pure CUT, BLEND, ENHANCED incision, FORCED COAG, SOFT COAG, BIPOLAR coagulation, and ABLATION.

  • Programmable RF EmissionAllows RF power emissions for programmable times as short as 10 milliseconds.

  • Digital ControlMicrocontroller-managed digital interface for precise power delivery and operational oversight.

  • Safety MonitoringContinuous monitoring of neutral electrode connection and patient/plate contact using a split neutral electrode.

  • User-Friendly OperationControl of output functions and power delivery directly from the handle, minimizing the need for the surgeon to divert attention from the surgical field.

DOUBLE ACTIVITY ‘OPERATION
• Two output channels for monopolar cutting
• Two independent settings and output channels for monopolar coagulation are more frequently used

CONTROLLED CUTTING PROCEDURES
• cutting currents for eschar-free incision
• Cutting current with selectable coagulating property for bleeding-controlled dissection
• Low capacitive coupling by current endoscopic procedures, Slow BLEND

DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * and two operators
• SPRAY COAG is achievable with a handpiece or pedal

WIDE BIPOLAR FEATURES
• Bipolar cutting with bleeding control
• Cutting current Slow BLEND
• Start and stop automatically activate separately

TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability of contact impedance between the patient’s body and the neutral plate is constantly verified by the electronic control Skin Plate Electronic Control called SPEC
• Continuous monitoring of leakage current
• Change in automatically compensated mains voltage before starting the RF power output

CUSTOM PROCEDURES
• Independent choice of coagulation currents and power levels of each of the two operators
• Ten configurable personal procedures and immediately recallable

CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• outputs for connections driven by argon plasma units and smoke aspirators

AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 300 HP
• Automatic diagnostic control of the actual complete electronic drive functionality and accessories, connected and coded report of found failures

Technical Data
  • Max output power monopolar pure CUT
    300 W – 300 Ω
  • Max output power monopolar cut-coag CUT80%
    250 W – 300 Ω
  • Max output power monopolar cut-coag CUT60%
    200 W – 300 Ω
  • Max output power monopolar cut-coag CUT40%
    150 W – 300 Ω
  • Max output power monopolar cut ENHANCED
    200 W – 500 Ω
  • Max output power monopolar cut-coag BLEND
    200 W – 300 Ω
  • Max output power monopolar coag SPEEDY
    100 W – 500 Ω
  • Max output power monopolar coag DEEP
    100 W – 200 Ω
  • Max output power monopolar coag SPRAY
    70 W – 2000 Ω
  • Max output power monopolar coag SPRAY ARGON
    70 W – 2000 Ω
  • Max output power of bipolar CUT
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT80%
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT60%
    120 W – 50 Ω
  • Max output power bipolar cut-coag CUT40%
    100 W – 50 Ω
  • Max output power bipolar cut-coag BLEND
    120 W – 150 Ω
  • Max output power bipolar coag COAG
    120 W – 50 Ω
  • Vessel sealing
    200 W – 50 Ω
  • Working frequency Monopolar / Bipolar
    425 kHz / 525 kHz
  • Patient circuit
    F
  • Selectable input voltage
    115 – 230 Vac
  • Mains frequency
    50 – 60 Hz
  • Electrical input power
    1000 VA
  • Size WxHxD
    470x150x400 mm
  • Weight
    17,5 Kgs

 

CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self-check control
H.F. Leakage currents control
Compensation for mains fluctuation

 

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Level of protection provided by housing: IP21
Electrical classification: CF

Reviews

There are no reviews yet.

Be the first to review “SURTRON 300 HP”

Your email address will not be published. Required fields are marked *

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare