SURTRON FLASH 200
Shipped From Abroad
The SURTRON FLASH 200 is a high-frequency electrosurgical unit designed for precision monopolar and bipolar surgeries, including microsurgical procedures, without causing tissue alterations. It offers programmable RF power emissions, allowing for operations with durations as short as 10 milliseconds. The device supports various surgical modes such as pure CUT, cut-coagulation BLEND, incision with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), BIPOLAR coagulation, and ABLATION. Its digital interface, managed by a microcontroller, ensures accurate power delivery and operational reliability. Safety features include continuous monitoring of the neutral electrode connection and patient/plate contact, with the capability to control output functions directly from the handle, allowing surgeons to maintain focus on the surgical field.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
SURTRON FLASH 200 is an electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON FLASH 200 can supply RF operative powers either for programmable times as short as hundreds of seconds. Through its performances, SURTRON FLASH 200 allows pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, BIPOLAR coagulation, and ABLATION. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of the job. SURTRON FLASH 200 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without turning the surgeon’s attention from the surgical field.
Key Features
-
Surgical Modes: Supports pure CUT, BLEND, ENHANCED incision, FORCED COAG, SOFT COAG, BIPOLAR coagulation, and ABLATION. led.it
-
Programmable RF Emission: Allows RF power emissions for programmable times as short as 10 milliseconds.
-
Digital Control: Microcontroller-managed digital interface for precise power delivery and operational oversight.
-
Safety Monitoring: Continuous monitoring of neutral electrode connection and patient/plate contact using a split neutral electrode. led.it
-
User-Friendly Operation: Control of output functions and power delivery directly from the handle, minimizing the need for the surgeon to divert attention from the surgical field.
Technical Data
Max output power CUT 200 W- 250 Ω
Max output power BLEND 120 W- 200 Ω
Max output power ENHANCED 120 W- 250 Ω
Max output power FORCED COAG 150 W- 150 Ω
Max output power SOFT COAG 90 W-100 Ω
Max output power BIPOLAR COAG 80 W-50 Ω
Working frequency 600 KHz
RF power pulse emission time 10 ms – 30 sec
RF power pulse interval 1 – 9
Patient circuit F
Selectable input voltage 115 – 230 VAC
Main frequency 50 – 60 Hz
Electrical input power: 350 VA
Size WxHxD 370x144x319 mm
Weight 6 Kgs
CONTROLS
Control Plate Circuit / OC patient
Control of the emitted power
Self-diagnosis
SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical classification: CF