SURTRON 120
Shipped From Abroad
The SURTRON 120 is a high-frequency electrosurgical unit, designed for light to medium surgical procedures. It offers both monopolar and bipolar functionalities, providing versatility across various clinical applications.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
SURTRON 120 is a high-frequency electrosurgical equipment that is suitable for light and medium surgery. SURTRON 120, through its performance, allows pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG, and, with a special adapter, BIPOLAR coagulation. The digital reading of delivered power and the monitoring of operative function by a microcontroller guarantee the absolute reliability of working conditions. SURTRON 120 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power, allows for the implementation of the surgical operation without diverting the surgeon’s attention from the surgical field.
Key Features
-
Operating Modes: Supports multiple modes including pure CUT, cut-coagulation BLEND, superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), and, with a special adapter, BIPOLAR coagulation.
-
Digital Interface: Equipped with a microcontroller for digital reading of delivered power and monitoring of operative functions, ensuring reliable performance.
-
Safety Measures: Features patient/plate circuit monitoring, output power monitoring, and self-check control. The connection of the neutral electrode is constantly monitored, with safety control of patient/plate contact using a split neutral electrode.
-
Underwater Cutting and Coagulation: Capable of performing procedures in wet environments, expanding its range of applications.
Technical Data
- Max output power CUT
120 W-250 Ω - Max output power BLEND
90 W-200 Ω - Max output power FORCED COAG
80W-150Ω - Max output power SOFT COAG
60 W-100 Ω - Max output power BIPOLAR
40 W-100 Ω - Working frequency 600 KHz
- Patient circuit F
- Selectable input voltage 115-230 VAC
- Main frequency 50-60 Hz
- Electrical input power: 300 VA
- Size WxHxD 254x104x288 mm
- Weight 5 Kgs
CONTROLS
- Patient/Plate circuit monitoring
- Output power monitoring
- Self-check control
SAFETY
- EN60601-1
- EN60601-1-2
- EN60601-2-2
- Electrical Class: I CF
- MDR 2017/745/UE Class: II b